Discharge + solar cycling
Solar Calc
Pack voltage, solar cycling, and skid charge — C-rates, extra Wh to refill, and whether each day recovers.
1 skid paralleled · 1S1P → 12 V 100 Ah on the bus
Amp-hours add when skid banks parallel onto this bus. Chemistry, SOC and LVD stay system-level.
Day is sunrise–sunset at the map pin. Night is the rest. Set night to 0 for a daytime-only skid. Both at 0 uses the sum of DC circuit watts as a 24/7 load.
Flat voltage, low sag, ~100% usable. Bulk 0.2C recommended, 0.05–0.5C window, charge factor ×1.03. Capacity 0.3%/°C vs 25 °C, no bulk below 0 °C.
Load sheds at this SOC and will not discharge further. LFP typically 10–20%. Lead-acid typically 50%.
MPPT ~96% into the bus. PWM delivers ~Isc × battery voltage. Set each skid's battery-side current cap on the solar skid cards.
Pack temperature lags air by ~6 h. Cold cuts capacity and raises IR; LFP/NMC will not bulk charge below 0 °C.
Solar array
Pin the site, then add parallel skids. Observed cloud uses the last 30 days at this pin.
33.869° S, 151.209° E
Match From / To to a logger or HMI export. Window is 7 days, capped at 93 d.
0° is flat. Equator-facing at ~latitude is a solid starting point. All skids share this facing and tilt.
Solar skids
Each skid has its own array, MPPT and battery bank. Banks parallel onto one DC bus — voltages must match.
1 skid · 200 W STC combined · 21.6 V max Voc · 12.2 A Isc sum · 1S1P 12 V 100 Ah
1S1P · 1 × 12 V 100 Ah → 12 V 100 Ah pack
This skid's bank parallels onto the 12 V DC bus. Parallel multiplies amp-hours; series stacks to the bus.
Leave blank for no current cap on this skid.
1S2P · 21.6 V Voc · 12.2 A Isc · 200 W STC
Cloudy block is centered on solar noon. Overcast hours drop beam and keep ~22% diffuse.
Mine trailers typically 10–20% film. 0.3–1%/day between washes. Specified yield already includes soiling.
Cable CSA
One-way length (m) and copper CSA (mm²) for each run. Leave CSA on Auto to size it, or pick the cable on the skid to check drop and ampacity.
Solar array
16 mm² · 0.42 V (2.4%) · rating 85 A
Battery bus
6 mm² · 0.26 V (2.1%) · rating 46 A
DC circuits
Each load off the main battery bus. If day and night load are 0, these watts are the system load.
No branch circuits yet — add lights, radio, instruments, or the 400 W payload.
Terminal voltage
Unassisted discharge — no solar, start SOC to low-battery cutoff
Sun arc
Solar elevation for the selected date. Shaded region is the cloudy block.
Daylight 11.2 h · sunrise 06:24 · sunset 17:36 · peak sun 46° · harvest 1.04 kWh/d · first cutoff 2026-08-28 02:24 · LVD 20% · pack 12–29 °C
Cloud used
Cloud preset applied each day of the window, with the day / night air you set.
Daily window
Harvest versus load for each calendar day in From – To. Sit this next to a logger kWh / SOC export from the unit.
Battery cycling
SOC over 7 days with load and PV. Amber fill is array power.
- Array does not restore the bank to the charge target before sunset on every day in the window.
Charge & skid
Restore energy includes load during sun, charge factor, controller, and wiring.
Nameplate 1.28 kWh · usable to LVD 1.02 kWh · no-sun autonomy 17h 4m · PSH 5.19 h · sun needed 7.90 h · charge factor ×1.03 · clip 0 Wh/d
LiFePO4 charge C-rate
peak 0.07 C · 7.04 APack lags air ~6 h. LiFePO4 absorb 13.85 V at mean bank temperature.
| Day | Dawn | Dusk | Min | Recovered | Charge |
|---|---|---|---|---|---|
| D1 | 69% | 94% | 65% | held | 34.5 Ah |
| D2 | 34% | 61% | 30% | short | 35.6 Ah |
| D3 | 20% | 50% | 20% | short | 36.0 Ah |
| D4 | 20% | 51% | 20% | short | 36.3 Ah |
| D5 | 20% | 51% | 20% | short | 36.5 Ah |
| D6 | 20% | 51% | 20% | short | 36.8 Ah |
| D7 | 20% | 52% | 20% | short | 37.0 Ah |
Cable CSA
Length and CSA you set, then drop and ampacity. Auto sizes to the allowance; pick a size to check the cable on the skid.
Solar array
Auto15.3 A · min 16 mm² · auto
Battery bus
Auto20.8 A · min 6 mm² · auto
Circuit voltage
Sun or backup on: charger is the PSU — DC bus sits above the battery posts. After dark: battery is the supply — posts sit above the bus and each downstream circuit by I×R. LVD opens the load disconnect: posts stay at pack voltage, bus and circuits go to 0 V until charge lifts SOC off the floor.
Add DC circuits in Cable CSA to plot far-end voltage on each run.
Discharge points
60 W day · 60 W night · 13.53 V start · 12.98 V end
| SOC | Time | Voltage |
|---|---|---|
| 100% | 0 min | 13.53 V |
| 75% | 17h 17m | 12.98 V |
| 50% | 17h 17m | 12.98 V |
| 25% | 17h 17m | 12.98 V |
| 20% | 17h 17m | 12.98 V |
Clear-sky POA from sun position at the map pin, panel tilt/azimuth, and Meinel air mass. Cloud is a noon-centered overcast block, a From–To Open-Meteo replay, the last 30 days at the pin, or a 5-year seasonal mean. Parallel skids share the bus and sum onto it. Estimate only — not a substitute for a site survey or manufacturer I–V data.